Used 1996 Trane air cooled liquid chiller. Model: RTAA110AYF01A1COBK. Rated capacity: 110 tons. Refrigerant: R-22. Refrigerant side factory test pressure hi/lo: 450/300 psig. System requirements: 200 V, 60 Hz, 3 phase. [2] Trane Helirotor compressors. Compressor A: model: CHHN060AKB0N069A, charge: 98 pounds, electrical requirements: 200 V, 233 RLA, 1190 LRA, 60 Hz, 3 phase. Compressor B, Model: CHHN050AKB0N057A, charge: 73 pounds, electrical requirements: 200 V, 192 RLA, 990 LRA, 60 Hz, 3 phase. [10] Condenser Fan Motors, 1.5 horse power, 200 V, 5.1 FLA, 60 Hz, 3 phase. Control circuit requirements: 115 V, 750 VA max, 60 Hz, single phase. Evaporator heat tape, 115 V, 420 VA max, 60 Hz, single phase. Includes Trane adaptive control panel. Inlets/outlets: [2] 4 inches diameter ports. Overall dimensions: 19 feet 3 inches length x 7 feet 4 ½ inches width x 7 feet 2 inches H.[h15][ACN550].
|
|
Click here for more information (pdf - 1,380.4 KB)
|
|
Stock No: re_ADSP01 |
Mfg: Trane |
Model: RTAA110AYF01A1COBK |
S/N: re_U96B32701
|
|
|
|
|
Used 1991 Trane Air Cooled Liquid Chiller- 200 Ton. Model: RTAA2004XB01A1B0E. Serial Number: U91E04416. Refrigerant: R-22. Refrigerant side factory test pressure hi/lo: 450/300 psig. System requirements: 460 V, 60 Hz, 3 phase. Trane Helirotor Compressor, Model: CHHB100TNB0N119AN, Serial Number: UA1E4418, electrical requirements: 460 V, 163 RLA, 896 LRA, 60 Hz, 3 phase. [14] Condenser Fan Motors, 1 horse power, 460 V, 2.8 RLA, 60 Hz, 3 phase. Control circuit requirements: 115 V, 750 RLA, 60 Hz, single phase. Evaporator heat tape, 115 V, 480 RLA, 60 Hz, single phase. Inlets/outlets: [2] 6 inches diameter flanged ports. Hours on compressors: unit A 678 hours run, unit B 1206 hours run. Overall dimensions: 23 feet length x 98 inches width x 93 inches height. [ACN741].
|
|
Click here for more information (pdf - 440.5 KB) Click here for additional information (pdf - 1,122.4 KB)
|
|
Stock No: re_SHCA128.44 |
Mfg: Trane |
Model: RTAA2004XB01A1B0E |
S/N: re_U91E04416
|
|
|
|
|
Used Giltron Water Recirculating Chiller. Model: WC-40, Serial Number: R-4144. Input Volts: 480. Tecumseh compressor, Model: AK100AT. Refrigerant: R-22. Capacity: 10,000 BTU per hour. Procon pump with Dayton motor: 1/4 horse power, 1725 rpm, 115 V, 5 amps, 60 Hz, 1 phase. Reservoir tank dimensions: 14 inches length x 10 inches width x 11 inches height. GE Fan motor: 1/20 horse power, 1550 rpm, 115 V, 2.5 amps, 60 Hz, 1 phase. Overall dimensions: 33 inches length x 15 inches width x 40 inches height.
|
|
Click here for more information (pdf - 249.9 KB)
|
|
Stock No: re_9a.FHF166.1a |
Mfg: Giltron |
Model: WC-40 |
S/N: re_R-4144
|
|
|
|
|
Used Giltron Water Recirculating Chiller. Model: WC-40, Serial Number: R-4138. Tecumseh compressor, Model: AK100AT. Refrigerant: R-22. Capacity: 10,000 BTU per hour. Procon pump with Dayton motor: 1/4 horse power, 1725 rpm, 115 V, 5 amps, 60 Hz, 1 phase. Reservoir tank dimensions: 14 inches length x 10 inches width x 11 inches height. GE Fan motor: 1/20 horse power, 1550 rpm, 115 V, 2.5 amps, 60 Hz, 1 phase. Overall dimensions: 33 inches length x 15 inches width x 40 inches height.
|
|
Click here for more information (pdf - 299.6 KB)
|
|
Stock No: re_9a.FHF167.1a |
Mfg: Giltron |
Model: WC-40 |
S/N: re_R-4138
|
|
|
|
|
Used Giltron Water Recirculating Chiller. Model: WC-40, Serial Number: R-4134. Tecumseh compressor, Model: AK100AT. Refrigerant: R-22. Capacity: 10,000 BTU per hour. Procon pump with Dayton motor: 1/4 horse power, 1725 rpm, 115 V, 5 amps, 60 Hz, 1 phase. Reservoir tank dimensions: 14 inches length x 10 inches width x 11 inches height. GE Fan motor: 1/20 horse power, 1550 rpm, 115 V, 2.5 amps, 60 Hz, 1 phase. Overall dimensions: 33 inches length x 15 inches width x 40 inches height.
|
|
Click here for more information (pdf - 257.3 KB)
|
|
Stock No: re_9a.FHF168.1a |
Mfg: Giltron |
Model: WC-40 |
S/N: re_R-4134
|
|
|
|
|
Used 1990 Snyder General / McQuay Air cooled Chiller 125 Tons. Model ALRC125C. Serial Number 5VJ0178900. Refrigerated System. [4] 35 horse power Compressors, 56 RLA, 283 LRA [EA], 460 V, 60 Hz, 3 phase, [12] Cond. Fan Motor. 1 horse power, 2.0/5.6 Fla, 9.9/14.5 LRA, 230/460 V, 60 Hz, 1 phase, [4] Crankcase HTRS. 0.87 A, 115 V, 60 Hz, 1 phase. [1] Evaporator HTRS. 3.2 A, 115 V, 60 Hz, 1 phase, single Power Supply, All Loads, 267 amps [min.], 300 amps [max.], 460 V, 60 Hz, 3 phase R-22 refrigerant, 141 lb. charge. Inlet: [1] 8 bolt 6 inches diameter flange. Outlet: [1] 6 inches diameter bolt. Overall dimensions: 18 feet 8 inches length x 91 inches width x 92 inches height. [ACN400]
|
|
Click here for Chiller Manual (pdf - 2,967.8 KB) Click here for Chiller Installation Guide (pdf - 5,073.9 KB) Click here for more information (pdf - 884.9 KB)
|
|
Stock No: re_cDPLS228.23 |
Mfg: Snyder General |
Model: ALRC125C |
S/N: re_5VJ0178900
|
|
|
|
|
Used McQuay Air Cooled Screw Chiller 200 Ton. Model ALS204A27, Serial Number 56F8139401. [2] Compressors. [14] Conditioning Fan. [2] Crankcase. [1] Evaporator. Supply Circuit 460 V, 60 hertz, 3 phase. 399 amps, max 500 amps. Refrigerant 22. Overall dimensions: 262 inches length x 84 inches width x 94 inches height.
|
|
Click here for more information (pdf - 360.6 KB)
|
|
Stock No: re_MQI003 |
Mfg: McQuay Snyder |
Model: ALS204A27 |
S/N: re_56F8139401
|
|
|
|
|
Used 1994 Dunham-Bush Air Cooled Chiller-225 Tons. Model ACDX225B. Serial Number 2864401A94F. Pressure Test: 400 PSI high side, 250 PSI low side. Unit: 460 V, 60 Hz, 3 phase. CNT: 115 V, 60 Hz, 1 phase. [4] Compressor Motors, Model: SSCA075AR, 103 RLA, 180 LRA, 460 V, 60 Hz, 3 phase. [4] Condenser Fan Motors, 1 horse power, 460 V, 2.4 amps, 60 Hz, 3 phase. [16] Condenser Fan Motors, 1-1/2 horse power, 460 V, 2.0 amps, 60 Hz, 3 phase. [4] Crankcase Heaters, 200 horse power, 115 V, 1.7 amps, 60 Hz, 1 phase. [3] Chiller Heater, 420 horse power, 115 V, 3.7 amps, 60 Hz, 1 phase. Cond. Of Service 599 gallons per minute/43 pgR-22 refrigerant with 484 lb. charge. Inlet: [1] 6 inches dia port. Outlet: [1] 8 bolt 6 inches dia flange. Overall dimensions: 37 feet 4 inches length x 100 inches width x 92-1/2 inches height. [ACN1035].
|
|
Click here for chiller manual (pdf - 519.7 KB) Click here for more information (pdf - 334.5 KB)
|
|
Stock No: re_DPLS230.43a |
Mfg: Dunham-Bush |
Model: ACDX225B |
S/N: re_2864401A94F
|
|
|
|
|
Used Carrier Air Cooled Chiller. Model: 30GTN110 620KA. Rated nominal cooling capacity: 110 tons. Refrigerant: R-22. [4] Carlyle compressors. Models: 06EF299610 and 06E6265610: 400/460V, 50/60Hz, 3 phase. [8] fans, 6 blades, 30 inch diameter, 950 rpm, 76000 cfm [6] at 2 hp, [2] 1.7 hp,460V, 60 Hz, 3 phase. Control power supply: 115V, 30 amps, 60 Hz, 1 phase. Comfort Link control panel enabling a cable ready connection to a Carrier Comfort Network[CCN]. Overall dimensions: 14 feet 7 inches L x 8 feet W x 8 feet 2 inches H.[ACN488].
|
|
Click here for more information (pdf - 507.9 KB)
|
|
Stock No: re_ABCC01 |
Mfg: Carrier |
Model: 30GTN110 620KA |
S/N: re_2202F57352
|
|
|
|
|
Used Carrier Air Cooled Chiller. Model: 30GTN110 620KA. Rated nominal cooling capacity: 110 tons. Refrigerant: R-22. [4] Carlyle compressors. Models: 06EF275610 and 06E6265610: 400/460V, 50/60Hz, 3 phase. [8] fans, 6 blades, 30 inch diameter, 950 rpm, 76000 cfm [6] at 2 hp, [2] 1.7 hp,460V, 60 Hz, 3 phase. Control power supply: 115V, 30 amps, 60 Hz, 1 phase. Comfort Link control panel enabling a cable ready connection to a Carrier Comfort Network[CCN]. Overall dimensions: 14 feet 7 inches L x 8 feet W x 8 feet 2 inches H.[ACN488].
|
|
Click here for more information (pdf - 488.2 KB)
|
|
Stock No: re_ABCC02 |
Mfg: Carrier |
Model: 30GTN110 620KA |
S/N: re_2202F57326
|
|
|
|
|
|